Foundation work using steel reinforcers etc., highway construction, installation work for vibrating machines.
Make sure to use one with an irregular surface for the edge of the anchor bar by flush cut. Use the hex head set screw or deformed steel bar.
Temperature(°C) | -5 | 5 | 20 | 30 |
---|---|---|---|---|
Initial Hardening Time (min.) | 300 | 60 | 30 | 15 |
(Do not move the anchor bar during the hardening time.)
Size | Dia*Length (mm) |
Volume (ml) |
Bolt used (deformed bar) |
Basic drill conditions |
Tensile strength (kN) |
Pcs./box | Pcs./ctn | JAN Code | |
---|---|---|---|---|---|---|---|---|---|
Dia(mm) | Depth(mm) | ||||||||
HC-10U* | 10.8×95 | 6.4 | M10, W3/8 | 12.0 | 95 | 36.1 | 10 | 200 | 4989270930100 |
D10 | 12.5 | 32.9 | |||||||
HC-12U* | 13.7×110 | 12.0 | M12, W1/2 | 15.0 | 110 | 47.2 | 10 | 200 | 4989270930117 |
D13 | 16.0 | 56.1 | |||||||
HC-16U* | 16.8×125 | 22.0 | M16, W5/8 | 19.0 | 140 | 85.4 | 10 | 100 | 4989270930124 |
D16 | 20.0 | 85.6 | |||||||
HC-20U* | 21.5×175 | 52.0 | M20, W3/4 | 25.0 | 180 | 117.6 | 10 | 100 | 4989270930131 |
D19 | 124.7 |